Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
1.
ROBRAC ; 27(83): 204-210, out./dez. 2018. ilus, graf, tab
Article in Portuguese | LILACS | ID: biblio-997302

ABSTRACT

Objetivo: avaliar o comportamento biomecânico de pré- -molar superior com presença de Lesões Cervicais Não Cariosas (LCNC) e submetido a três carregamentos oclusais distintos pelo método de elementos finitos tridimensional (3D). Material e método: nove modelos tridimensionais elásticos foram gerados, com propriedades ortotrópicas e isotrópicas: Hígido (H); LCNC não restaurada (LCNC) e LCNC restaurada com resina composta (RC); sendo todos estes modelos submetidos a três carregamentos: Axial (A), Oblíquo vestibular (V) e Oblíquo palatino (P). Os carregamentos tiveram intensidade de 150 N e a restrição de deslocamento foi realizada na base e lateral dos ossos cortical e medular. Os resultados foram gerados em tensão máxima e mínima principal. Resultados: O carregamento axial apresentou padrões de tensão mais favoráveis, independente da característica da região cervical. O carregamento palatino mostrou maior acúmulo de tensão de tração na região cervical vestibular e o carregamento vestibular resultou em maior tensão de compressão na tábua óssea vestibular. A presença de LCNC foi fator intensificador para o aumento da concentração de tensão na região cervical. A simulação da restauração com resina composta promoveu um comportamento biomecânico simular ao do hígido. Conclusões: que o carregamento palatino pode estar mais associado com a presença de LCNCs e o vestibular com a presença de recessão gengival. O ajuste oclusal e a restauração da LCNC são indicados para tornar o padrão de tensão mais favorável para o remanescente dentário.


Objective: to evaluate the biomechanical behavior of maxillary premolar with the presence of NCCL and submitted to three distinct occlusal loads, using the three-dimensional (3D) finite element analysis. Methods: nine three-dimensional elastic models were generated, with orthotropic and isotropic properties: Sound (H); Unrestored NCCL (NCCL) and NCCL restored with composite resin (RC); All models were submitted to three loads: Axial (A), Buccal (V) and Palataline (P). The loads intensity was 150 N and the displacement restriction was performed at the base and lateral of the cortical and medullary bones. The results were generated at maximum and minimum principal stress. Results: the axial loading presented more favorable stress pattern, independent of the characteristic of the cervical region. The palataline loading showed a greater concentration of tensile stress in the buccal cervical region and the buccal loading resulted in a higher compression stress in the buccal bone. The presence of NCCL was a relevant factor for increase concentration of stress in the cervical region. The simulation of the restoration with composite resin promoted a biomechanical behavior similar to that of the sound tooth. Conclusion that the palataline loading may be more associated with the presence of NCCLs and the vestibular with the presence of gingival recession. The occlusal adjustment and the restoration of NCCLs are indicated to produce the stress pattern more favorable for the dental remaining.

2.
Braz. dent. j ; 28(3): 324-329, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888659

ABSTRACT

Abstract Conservative approach, including occlusal splint therapy, is the first option to treat temporomandibular disorders (TMD), because of its reversibility. The present study analyzed the effect of the articular disc position and occlusal splints use on the stress distribution on this disc. A two-dimensional (2D) finite element (FE) model of the temporomandibular joint with the articular disc at its physiologic position was constructed based on cone-beam computed tomography. Three other FE models were created changing the disc position, according to occlusal splint use and anterior disc displacement condition. Structural stress distribution analysis was performed using Marc-Mentat package. The equivalent von Mises stress was used to compare the study factor. Higher stress concentration was observed on the intermediate to anterior zone of the disc, with maximum values over 2MPa. No relevant difference was verified on the stress distribution and magnitude comparing disc positions and occlusal splint use. However, there was stress reduction arising from the use of the occlusal splints in cases of anterior disc displacement. In conclusion, based on the generated FE models and established boundary conditions, the stress increased at the intermediate zone of the TMJ disc during physiological mandible closure. The stress magnitude was similar in all tested situations


Resumo Abordagens conservadoras, incluindo o uso de placas oclusais, são as primeiras opções de tratamento para disfunção temporomandibular (DTM), devido à sua reversibilidade. O presente estudo analisou o efeito da posição do disco articular e do uso de placa oclusal na distribuição de tensões no disco. Um modelo bidimensional (2D) de articulação temporomandibular (ATM) em posição fisiológica, foi desenvolvido para análise pelo método de elementos finitos, baseado em imagens de tomografia computadorizada do tipo cone-beam. Três outros modelos foram criados alterando a posição do disco de acordo com o uso de placa oclusal e condição de deslocamento anterior do disco. Uma análise estrutural da distribuição de tensões foi realizada no software Marc-Mentat, e equivalente Von Mises foi usado para comparar os fatores em estudo. Maior concentração de tensão foi observada na zona intermediária para a zona anterior do disco, atingindo valores máximos acima de 2 MPa. Nenhuma diferença relevante foi verificada na localização e magnitude das tensões quando comparadas as posições do disco e uso de placa oclusal. No entanto, houve pequena redução das tensões decorrente do uso de placa oclusal em caso de deslocamento anterior do disco. Conclui-se que mediante os modelos criados e condições de contorno estabelecidas, as tensões na zona intermediária do disco aumentam durante o fechamento mandibular fisiológico. A magnitude das tensões foi semelhante em todas as situações testadas


Subject(s)
Humans , Female , Adult , Temporomandibular Joint Disorders/therapy , Occlusal Splints , Temporomandibular Joint Disc/physiopathology , Dental Stress Analysis , Computer Simulation , Temporomandibular Joint Disorders/diagnostic imaging , Temporomandibular Joint Disc/diagnostic imaging , Finite Element Analysis , Cone-Beam Computed Tomography
3.
Biosci. j. (Online) ; 32(3): 786-804, may/june 2016. ilus, tab
Article in English | LILACS | ID: biblio-965523

ABSTRACT

The dentoskeletal effects produced by the bonded expander, principally the vertical ones, are controversial in the literature when compared with the effects produced by the hyrax, and have also been scarcely studied by means of cone-beam computed tomography (CBCT). This study aimed to evaluate the horizontal and vertical dentoskeletal effects produced by the bonded expander and by the hyrax using CBCT. The study sample consisted of ten patients, divided equally into two groups according to facial and cephalometric features: group 1, vertical facial growth pattern (two males, three females; mean age, 7.7 years) and group 2, normal facial growth pattern (three males, two females; mean age, 8.3 years), treated by bonded expander and hyrax, respectively. The patients were subjected to a CBCT scan before expansion and another scan four months after the end of the activations, when the expander was removed. Within each group and between the groups the horizontal and vertical effects were assessed using Student's t-test. The sample size was predetermined, and 5 patients were needed in each group to detect the differences at P < 0.05 with 90% power. Among the horizontal changes assessed, the nasal floor width (P = 0.03) and the greater internal width in the posterior region (P = 0.00) showed a statistically significant increase only for group 1, and the mandibular molar verticality showed a statistically significant increase only for group 2. The vertical changes showed no statistical differences within groups (P > 0.05). Comparing the two groups there were no statistical differences for any assessed change (P > 0.05). Considering there were no differences of the effects between the appliances, the bonded expander produced no greater vertical control compared to the hyrax. Nevertheless, further study is recommended in a larger sample size using CBCT.


Os efeitos dentoesqueléticos produzidos pelo expansor colado, principalmente os efeitos verticais, são controversos na literatura quando comparados aos efeitos produzidos pelo expansor hyrax, e pouco estudado por meio de tomografia computadorizada de feixe cônico (TCFC). O objetivo deste estudo foi avaliar os efeitos dentoesqueléticos horizontais e verticais produzidos pelo expansor colado e pelo hyrax, utilizando-se TCFC. A amostra do estudo consistiu de cinco pacientes, divididos igualmente em dois grupos de acordo com as características faciais e cefalométricas: grupo 1, padrão de crescimento facial vertical (dois do sexo masculino, três do sexo feminino, idade média 7,7 anos), e grupo 2, padrão de crescimento facial normal (três do sexo masculino, duas do sexo feminino, idade média 8,3 anos) tratados com expasor colado e hyrax, respectivamente. Os pacientes foram submetidos à escaneamento de TCFC antes da expansão e após quatro meses da última ativação, quando o expansor foi removido. Nas comparações intra e inter-grupos, os efeitos horizontais e verticais foram avaliados por meio do teste t de Student. O tamanho da amostra foi pré-determinado, e cinco pacientes foram necessários em cada grupo para detectar diferenças para P < 0,05 e com 90% de poder. Dentre as alterações horizontais avaliadas, a largura do assoalho nasal (P = 0,03) e a maior largura nasal interna na região posterior (P = 0,00) mostraram aumento estatisticamente significante apenas para o grupo 1, e a verticalização do molar inferior mostrou aumento estatisticamente significante apenas no grupo 2 (P = 0,01). As alterações verticais avaliadas não demonstraram diferença estatística intra-grupos. Na comparação inter-grupos não foi encontrada diferença estatística em nenhum parâmetro avaliado (P > 0,05). Dado que não houve diferença na comparação inter-grupos, o expansor colado não produziu maior controle vertical em relação ao hyrax. No entanto, é recomendada a realização de mais estudos com maior amostra utilizando-se TCFC.


Subject(s)
Orthodontic Appliances , Palatal Expansion Technique , Cone-Beam Computed Tomography , Malocclusion
4.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Article in English | LILACS | ID: lil-777185

ABSTRACT

To evaluate the association between temporomandibular disorder (TMD) and anxiety, quality of sleep, and quality of life in nursing professionals at theHospital de Clínicas de Uberlândiaof theUniversidade Federal de Uberlândia – HCU-UFU (Medical University Hospital of the Federal University of Uberlândia), four questionnaires were given to nursing professionals. The questionnaires were completed by 160 of these professionals. The Fonseca’s questionnaire was used to evaluate the presence and severity of TMD, the IDATE was used to evaluate anxiety, the SAQ was used to evaluate quality of sleep, and the SF-36 was used to evaluate quality of life. Forty-one nurses (25.6%) reported having no TMD (Fonseca’s questionnaire score ≤ 15), 66 (41.3%) had mild TMD (Fonseca’s questionnaire score 20–40), 39 (24.4%) had moderate TMD (Fonseca’s questionnaire score 45–65), and 14 (8.8%) had severe TMD (Fonseca’s questionnaire score ≥ 70). According to Fonseca’s questionnaire, the presence of TMD was associated with trait anxiety, but the TMD severity was associated with state anxiety classification (mild, moderate, severe). The SAQ score differed significantly from Fonseca classification. The Fonseca’s questionnaire score correlated negatively with the score of each dimension of the SF-36 (r = –0.419 to –0.183). We conclude that TMD is common among nursing professionals; its presence was associated with trait anxiety, and its severity was associated with state anxiety. Hence, the presence of TMD may reduce quality of sleep and quality of life.


Subject(s)
Female , Humans , Male , Anxiety/complications , Nurses/psychology , Quality of Life/psychology , Sleep Wake Disorders/complications , Temporomandibular Joint Disorders/complications , Analysis of Variance , Anxiety/physiopathology , Anxiety/psychology , Occupational Diseases/complications , Occupational Diseases/physiopathology , Occupational Diseases/psychology , Severity of Illness Index , Surveys and Questionnaires , Sleep Wake Disorders/physiopathology , Sleep Wake Disorders/psychology , Temporomandibular Joint Disorders/physiopathology , Temporomandibular Joint Disorders/psychology
5.
Braz. j. oral sci ; 13(4): 281-287, Oct-Dec/2014. tab
Article in English | LILACS, BBO | ID: lil-732346

ABSTRACT

Aim: To investigate the prevalence of temporomandibular disorders (TMD) in undergraduate students and to correlate its prevalence with occlusal factors and parafunctional habits. Methods: 201 undergraduate students were evaluated. The Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) was filled out at the beginning of the study, followed by occlusal analysis based on morphological and functional alterations. The identification of tooth grinding and clenching was carried out by self-reports. Statistical analysis was based on chi-square and multivariate logistic regression analyses. p-value for all statistical analysis was set at 5%. Results: According to RDC/TMD, 18.4% of subjects experienced myofascial pain (G-MPD), and 12.4% had joint disorder with disc displacement (G-DD). Tooth clenching was statistically associated with TMD (p=0.000). In the occlusal factors, overjet showed statistically significant correlation only with myofascial pain. No association between functional alteration and TMD was found. No statistically significant correlation was found between G-DD and occlusal alterations or parafunctional habits. Conclusions: Overjet and tooth clenching were correlated with G-MPD. Occlusal alterations or parafunctional habits did not show correlation with G-DD.


Subject(s)
Humans , Male , Female , Bruxism , Temporomandibular Joint Disorders/epidemiology , Dental Occlusion , Myofascial Pain Syndromes
6.
Braz. dent. j ; 24(1): 64-67, 2013. graf
Article in English | LILACS | ID: lil-671350

ABSTRACT

The aim of this study was to evaluate the ability to identify occlusal prematurity by images from paraxial slices of cone-beam computed tomography (CBCT). For such purpose, a pilot study was performed in which 16 asymptomatic young patients were subjected to a clinical examination, including a careful occlusal analysis and then individual deprogrammer devices (“Lucia's JIG”) were fabricated. Premature contacts were clinically identified in centric relation (CR) for each patient by jaw manipulation and interocclusal marking with articulating paper (Accufilm). Subsequently, these devices were adjusted in CR and used during the tomographic exams in such a way that CBCT in CR could be obtained. After routine processing, the images were analyzed in order to identify occlusal prematurity on the displayed images by 30 professionals divided according to areas of activity (occlusion specialist, general practitioner and radiologist; n=10 per area) and time of professional experience (less than 5, between 5 and 10, and over 10 years). By comparing the premature contacts identified in the clinical analysis and CBCT images, an agreement index between these two variables was calculated. Data were analyzed statistically by ANOVA and Scott-Knott test (α=0.05). The results showed that the identification of occlusal prematurity by paraxial CBCT slices was proven to be a method of average reliability.


O objetivo deste estudo foi avaliar a capacidade de identificação de prematuridades oclusais por meio de imagens obtidas de cortes paraxiais de tomografias computadorizadas de feixe cônico. Para este fim, realizou-se um estudo piloto em que 16 pacientes jovens assintomáticos foram submetidos ao exame clínico, incluindo análise oclusal criteriosa, e em seguida foram confeccionados dispositivos desprogramadores individuais (“JIG de Lucia”). Mediante manipulação mandibular e marcação interoclusal com papel carbono (Accufilm) identificou-se clinicamente o contato prematuro em relação cêntrica (RC) de cada paciente. Posteriormente estes dispositivos foram ajustados na posição de contato cêntrico e utilizados durante os exames tomográficos para que se pudessem obter imagens tomográficas na posição de relação cêntrica. Após o processamento das imagens, estas foram analisadas com o intuito de identificar prematuridades oclusais nas imagens visualizadas por 30 profissionais divididos de acordo com as áreas de atuação (Oclusão, Clínica Geral e Radiologia, n=10 para cada área) e tempo de exercício profissional (<5; entre 5 e 10; e >10 anos). Mediante comparação entre os contatos prematuros identificados na análise clínica oclusal e as imagens tomográficas apontadas pelos profissionais como áreas de contatos prematuros, foram calculados os índices de concordância entre essas duas variáveis. Os dados obtidos foram analisados estatisticamente pela Análise de Variância ANOVA e teste de Scott-Knott (α=0,05). Os resultados deste estudo demonstraram que a identificação de prematuridades oclusais por meio de cortes paraxiais de tomografias computadorizadas de feixe cônico mostrou-se como um método de confiabilidade média.


Subject(s)
Adolescent , Adult , Humans , Young Adult , Cone-Beam Computed Tomography , Dentists , Malocclusion , Analysis of Variance , Centric Relation , Clinical Competence , Imaging, Three-Dimensional/methods , Jaw Relation Record , Malocclusion/diagnosis , Observer Variation , Pilot Projects , Specialties, Dental
7.
Braz. dent. j ; 23(5): 484-489, Sept.-Oct. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-660348

ABSTRACT

This in vitro study analyzed the effect of different load application devices on fracture resistance and failure mode of maxillary premolars restored with composite resin. Sixty human maxillary premolars received standardized mesio-occluso-distal cavity preparations and were restored with composite resin. The specimens were randomly divided into 6 groups (n=10). Compressive loading was applied using 6 different metallic devices: S2: 2-mm sphere; S6: 6-mm sphere; C2: 2-mm cylinder; C6: 6-mm cylinder; WS: wedge shape device; and MAT: individualized metallic antagonist tooth. Data were analyzed statistically using one-way ANOVA and Tukey's test (α=0.05). The failure mode was recorded based on the 4 sequential levels. Statistical analysis revealed that WS presented significantly higher fracture resistance than S6 and C6. No significant difference was found among MAT, C2, S2 and S6. Sphere and cylinder with 6 mm were similar, with the lowest values of all groups. MAT presented the least number of catastrophic failures while C2, S2 and WS presented the highest. The type of load application device influences significantly the behavior of the teeth-restoration complex during mechanical fracture resistance test.


Este estudo avaliou o efeito de diferentes tipos de dispositivos de aplicação de carga na resistência à fratura de pré-molares superiores restaurados com resina composta. Sessenta pré-molares humanos receberam preparo mésio-ocluso-distal padronizado e as cavidades foram restauradas com resina composta. As amostras foram aleatoriamente divididas em 6 grupos (n=10). Carregamento de compressão foi realizado usando seis diferentes dispositivos metálicos de aplicação de carga: S2 e S6: esfera de 2 mm e 6 mm de diâmetro respectivamente; C2 e C6: cilindro de 2 mm e 6 mm de diâmetro respectivamente; WS: lâmina de faca e MAT: antagonista individualizado em metal. Os resultados foram submetidos à análise de variância e teste de Tukey (p<0,05). O modo de falha foi classificado em 4 níveis e estão apresentado em porcentagem. O dispositivo WS resultou em maior resistência a fratura de pré-molares que S6 e C6. Não houve diferença estatística entre os grupos MAT, C2, S2 e S6. Menor resistência foi verificada com o uso de S6 e C6. O dispositivo MAT resultou em menor número de falhas catastróficas enquanto nos grupos C2, S2 e WS essas falhas foram significativas. O tipo de dispositivo de aplicação de carga influenciou significativamente no comportamento do complexo dente-restauração durante o teste de resistência à fratura.


Subject(s)
Humans , Composite Resins/chemistry , Dental Restoration, Permanent , Equipment Failure Analysis/instrumentation , Materials Testing/instrumentation , Tooth Fractures , Analysis of Variance , Bicuspid , Equipment Failure Analysis/methods
8.
Braz. dent. j ; 23(5): 559-563, Sept.-Oct. 2012. graf
Article in English | LILACS | ID: lil-660360

ABSTRACT

Soy milk (SM) is widely consumed worldwide as a substitute for cow milk. It is a source of vitamins, carbohydrates and sugars, but its capacity to preserve cell viability has not been evaluated. The purpose of the present study was to investigate the efficacy of SM to maintain the viability of human fibroblasts at short periods compared with different cow milks. Human mouth fibroblasts were cultured and stored in the following media at room temperature: 10% Dulbecco's Modified Eagle Medium (DMEM) (positive control group); long shelf-life ultra-high temperature whole cow milk (WM); long shelf-life ultra-high temperature skim cow milk (SKM); powdered cow milk (PM); and soy milk (SM). After 5, 15, 30 and 45 min, cell viability was analyzed using the MTT assay. Data were analyzed statistically by the Kruskal-Wallis test with post-analysis using the Dunn's method (α=0.05). SKM showed the lowest capacity to maintain cell viability in all analyzed times (p<0.05). At 30 and 45 min, the absorbance levels in control group (DMEM) and SM were significantly higher than in SKM (p<0.05). Cell viability decreased along the time (5-45 min). The results indicate that SM can be used as a more adequate storage medium for avulsed teeth. SKM was not as effective in preserving cell viability as the cell culture medium and SM.


O leite de soja (LS) é largamente consumido em todo o mundo como substituto para o leite bovino. Este é uma fonte de vitaminas, carboidratos e açúcares, mas a sua capacidade para preservar a viabilidade celular não foi avaliada. A finalidade do estudo foi investigar a eficácia do LS em manter a viabilidade de fibroblastos humanos em períodos curtos em comparação com diferentes leites bovinos. Fibroblastos de boca humanos foram cultivados e armazenados nos seguintes meios à temperatura ambiente: 10% de meio Dulbecco's Modified Eagle (DMEM) (grupo controle positivo); leite bovino integral longa vida (LI); leite bovino desnatado longa vida - LD; leite em pó - LP; leite de soja - LS. Depois de 5, 15, 30 e 45 min, a viabilidade celular foi analisada usando o método de MTT. Os dados foram analisados estatisticamente pelo teste de Kruskal-Wallis e posteriormente usando o método de Dunn (α=0,05). O grupo LD apresentou a menor capacidade para manter a viabilidade celular em todos os tempos analisados (p<0,05). Aos 30 e aos 45 min, os níveis de absorbância no grupo controle (DMEM) e LS foram significativamente maiores que no grupo LD (p<0,05). A viabilidade celular diminuiu ao longo do tempo (5-45 min). Os resultados indicaram que LS pode ser usado como meio de armazenamento mais adequado para dentes avulsionados. LD não foi eficaz na preservação da viabilidade das células como o meio de cultura de células e o LS.


Subject(s)
Animals , Humans , Fibroblasts/physiology , Organ Preservation Solutions , Periodontal Ligament/cytology , Soy Milk , Cell Culture Techniques , Cell Survival , Culture Media , Milk
10.
Braz. oral res ; 26(1): 29-35, Jan.-Feb. 2012. ilus, tab
Article in English | LILACS | ID: lil-622928

ABSTRACT

The magnitude of occasional discrepancies between the centric relation and maximal intercuspation positions remains a controversial subject. This study quantitatively evaluated the possible discrepancies in the condyle/mandibular fossa relationship between these positions using cone-beam computed tomography. Twenty young and asymptomatic volunteers were distributed equally into normal occlusion and Angle Class I, II and III malocclusion groups. They were submitted to one tomographic scan in maximal intercuspation and one in centric relation. Measurements were performed on lateral and frontal cuts of the patients' temporomandibular joints, and the data collected were compared using Student's t test at a significance level of 5%. The results showed that there were no statistically significant differences between the centric relation and maximal intercuspation positions in young and asymptomatic patients with practically intact dentitions using cone-beam computed tomography.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Mandibular Condyle , Centric Relation , Cone-Beam Computed Tomography/methods , Malocclusion/physiopathology , Mandibular Condyle/anatomy & histology , Organ Size , Reference Values , Reproducibility of Results , Temporomandibular Joint
11.
Braz. dent. j ; 23(6): 686-691, 2012. ilus, tab
Article in English | LILACS | ID: lil-662427

ABSTRACT

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


O objetivo deste estudo foi avaliar o efeito de diferentes parâmetros de solda a plasma verificando a resistência flexural de barras de liga de titânio (Ti-6Al-4V). Quarenta espécimes de Ti-6AL-4V e dez espécimes de liga de NiCr foram preparados (40 mm de altura e 3,18 mm de diâmetro) e divididos em 5 grupos (n=10). As barras de liga titânio do grupo controle não foram seccionadas e nem submetidas a processo de soldagem. Os grupos PL10, PL12 e PL14, continham barras de titânio seccionadas e soldadas com uma corrente de 3 A por períodos de 10,12 e 14 ms, respectivamente. O grupo NCB consistiu de barras de liga de NiCr soldadas pelo método de brasagem convencional. Em seguida as barras foram submetidas ao teste de flexão de três pontos e os valores obtidos foram transformados em resistência flexural (MPa). Análise estatística foi realizada usando ANOVA de fator único e o teste Tukey com o nível de significância de 0,05. Diferença estatística foi verificada entre os grupos avaliados (p<0,001), com os maiores valores pra o grupo controle. Não foram encontradas diferenças entre os grupos de solda plasma (p>0,05). O grupo NCB apresentou os menores valores de resistência flexural embora tenha sido estatisticamente semelhante ao grupo PL14. Não houve diferença significante na profundidade de penetração entre os grupos de solda plasma (p=0,05). Três espécimes representativos foram aleatoriamente selecionados para serem avaliados por meio de microscopia eletrônica de varredura. A composição das regiões soldadas foi verificada por meio de espectroscopia por energia dispersiva. Este estudo fornece informações iniciais de parâmetros para permitir a utilização de soldagem plasma durante a fabricação de estruturas em liga de titânio.


Subject(s)
Humans , Dental Alloys/chemistry , Dental Soldering/methods , Plasma Gases/chemistry , Titanium/chemistry , Argon/chemistry , Chromium Alloys/chemistry , Dental Soldering/instrumentation , Materials Testing , Microscopy, Electron, Scanning , Pliability , Spectrometry, X-Ray Emission , Stress, Mechanical , Surface Properties , Welding/instrumentation , Welding/methods
12.
UNOPAR Cient., Ciênc. biol. saude ; 13(ESP): 369-374, dez. 2011.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-621750

ABSTRACT

A Terapia Periodontal de Suporte (TSP) denota a necessidade básica dos procedimentos terapêuticos para que os pacientes, por meio de esforços próprios, possam controlar a infecção periodontal, sendo considerada abordagem que está diretamente relacionada com o sucesso da terapia periodontal como um todo. Inúmeras experiências clínicas sobre os efeitos em longo prazo do tratamento de periodontite têm demonstrado que manutenção profissional cuidadosa pós-terapêutica é parte integrante do tratamento periodontal, constituindo o único meio de garantir a manutenção por longo período dos efeitos benéficos da terapia. Assim, o objetivo desse artigo é revisar alguns aspectos relacionados à TSP, incluindo filosofia e periodicidade do tratamento, índices para controle periodontal, abordagem profissional, recursos e técnicas disponíveis bem como o processo de reavaliação de pacientes. A avaliação desses tópicos permite afirmar que a TSP é pré-requisito indiscutível para garantir resultados benéficos dos tratamentos com manutenção dos níveis de inserção clínica por longos períodos de tempo, mesmo que abordagens em relação à avaliação contínua do risco nos níveis do paciente, dos dentes e dos sítios dos dentes representem desafio para o conceito da TSP.


Supportive Periodontal Therapy (SPT) denotes the basic need of therapeutic procedures in order patients can control periodontal infection through their own efforts, considering the approach that is directly related to the success of the periodontal therapy as a whole. Several clinical experiences on long-term effects of periodontitis treatments have shown that a careful professional post-therapeutic maintenance therapy is part of the periodontal treatment, consisting in the only means of assuring the maintenance of the therapy beneficial effects in long term. This paper aims to review a few aspects related to SPT, including philosophy and frequency of treatment, periodontal control indexes, professional approach, available resources and techniques, as well as the process of reassessing patients. The analysis of those topics allows us to state that SPT is an undeniable prerequisite to ensure beneficial outcomes of periodontal treatment with maintenance of clinical attachment levels for long periods, even though approaches to continuous assessment of the patient?s risk levels, teeth and tooth sites pose a challenge to SPT concept.

13.
RFO UPF ; 16(2)maio-ago. 2011.
Article in Portuguese | LILACS | ID: lil-611997

ABSTRACT

Objetivo: analisar a performance mastigatória (PM) em pacientes submetidos ao uso de próteses removíveis imediatas (PRTI). Métodos: Selecionaram-se três pacientes que foram submetidos aos testes de performance mastigatória com dentes naturais (DN) e com PRTI superior, inferior e bimaxilares, mantendo o padrão oclusal, imediatamente antes das exodontias e seis meses após a instalação e reembasamento dessas. Um simulador de alimento "Optocal" foi mastigado por quarenta golpes, monitorados visualmente por um único examinador calibrado. O material mastigado foi colocado num conjunto de oito peneiras granulométricas. Completada a tamisação, o conteúdo retido em cada peneira foi secado em estufa e pesado individualmente. Resultados: Os pacientes reabilitados com PRTI bimaxilares e superior demonstraram comportamento mastigatório semelhante, resultando em redução da performance mastigatória. No entanto, a paciente com PRTI inferior demonstrou melhora na PM. Conclusão: O teste de performance mastigatória demonstrou ser um importante auxiliar na compreensão e avaliação da função mastigatória diante dos procedimentos clínicos adotados.

14.
RGO (Porto Alegre) ; 58(3): 333-337, jul.-set. 2010. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-874140

ABSTRACT

Objetivo: Avaliar as condições de densidade cicatricial radiográfica ao longo de implantes bioativos recobertos com proteína morfogenética óssea recombinante humana tipo-2 (rhBMP-2) (implante experimental) em comparação com implantes de superfície rugosa (implante controle). Métodos: Foram selecionados 12 pacientes com indicação de implantes em áreas posteriores de mandíbula e maxila, sendo colocados dois implantes de forma contígua: implantes experimentais e implantes controles. Os implantes foram fixados ad modum Brånemark. Tomadas radiográficas foram feitas em quatro momentos distintos: inicial, pós-cirúrgico, 3 meses e 8 meses, para aplicação posterior de técnica digital de subtração das imagens. Foram feitos ajustes de geometria e contraste para posterior comparação dos valores de densidade radiográfica entre os diversos períodos de análise, levando-se em conta a radiografia inicial como valor de constante de correção. Os valores de densidade radiográfica foram submetidos a tratamento estatístico pelo teste t de Student, com valores corrigidos para arco seno e p=0.00. Resultados: Os implantes experimentais tratados com rhBMP-2 apresentaram melhora significativa no aumento da densidade óssea pós-operatória (39,77) p<0,05, quando comparado aos implantes controles (8,21) p<0,05. Conclusão: O tratamento de superfície com rhBMP-2 mostrou-se promissor na otimização da densidade óssea, fato relevante no estudo de áreas de risco para perda de implantes odontológicos.


Objective: Evaluate clinically and radiographically the conditions of bone density around the experimental bioactive implants that are covered with Bone Morphogenetic Protein recombinant human type-2 (rhBMP-2) (IE) and to compare it to that obtained whit rough- surface implants (IC). Methods: Twelve patients with indication for treatment of dental implants were included in this study, in which each received 2 implants: IE (rhBMP-2) and IC (rough-surface implants). The surgical procedure was done in according to the Brånemark protocol. Digital subtraction technique was used to assess the dental implants in four moments: initial, after-surgical, 3 months and eight months. Results: There was significantly different among the treatments of dental implants (p<0.05). The increase of bony density was better to IE (39.77) than IC (8.21). Conclusion: These findings suggest that rhBMP-2-coated implants can stimulated bone formation around dental implants and may be an alternative in treatment for low bone density sites.


Subject(s)
Humans , Bone Density , Dental Implants , Radiography , Case-Control Studies
15.
Braz. j. oral sci ; 9(2): 128-132, Apr.-June 2010. ilus, tab
Article in English | LILACS, BBO | ID: lil-578077

ABSTRACT

Aim: To evaluate the root topography of human teeth affected by periodontitis, after different root surface treatments. Methods: Forty-two periodontally affected single-rooted human teeth were selected and randomly divided into 7 groups (n=6): Cont- control group, which received no treatment; Sca- root surface scaling and root planning with curettes; ScaPh- Sca followed by 37%phosphoric acid gel etching for 15 s; ScaEdta- Sca followed by 24% EDTA gel pH 7 for 1 min; ScaCi- Sca followed by 30% citric acid pH 1.6 for 5 min; ScaTe- Sca followed by - mixture obtained by 500 mg tetracycline capsule dissolved in saline solution for 3 min; ScaTeg- Sca followed by 0.2 g/mL tetracycline gel pH 1.8 for 1 min. The specimens were analyzed by scanning electronic microscopy to verify the presence of calculus, demineralization level and residues of the product. Results: Calculus deposits were found in all control specimens. ScaEdta, ScaCi and ScaTeg removed completely calculus deposits and resulted in adequate demineralization without smear layer and smear plug on root surface. ScaTe produced great tetracycline residues with several demineralization areas on root dentin surface. Conclusions: ScaEdta, ScaCi and ScaTeg produced clean root surfaces associated with regular dentin demineralization.


Subject(s)
Humans , Dental Scaling , Tooth Demineralization/chemically induced , Periodontitis/drug therapy , Tooth Root , Smear Layer , Citric Acid/therapeutic use , Surface Properties , Tetracycline/therapeutic use
16.
Odonto (Säo Bernardo do Campo) ; 18(35): 5-13, jan.-jun. 2010. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-578081

ABSTRACT

Introdução: os protocolos de avaliação das assimetrias faciais em pacientes com disfunção temporomandibular são, em grande parte, realizados por meio da avaliação cefalométrica, que possibilita a visualização, mensuração e análise apenas do tecido duro. A análise facial pela biofotogrametria computadorizada tem sido utilizada como meio auxiliar diagnóstico, não expondo o indivíduo a radiação nociva, promovendo avaliação das estruturas craniofaciais, musculares e a disposição do tecido adiposo. Objetivo: avaliar a assimetria facial em pacientes com disfunção temporomandibular por meio da biofotogrametria computadorizada. Material e métodos: a amostra consistiu de 36 pacientes com disfunção temporomandibular (31 mulheres e 05 homens), e 11 indivíduos controles (06 mulheres e 05 homens). Para a seleção e classificação da amostra foi utilizado o Índice Clínico de Fonseca (1994), seguido do exame físico, odontológico e fisioterapêutico. Resultados: foram encontradas diferenças significativas (p=0,041) quando comparados o ângulo referente à boca, entre os lados direito e esquerdo, nos pacientes com disfunção temporomandibular. Conclusão: alterações na simetria facial podem estar presentes em pacientes com disfunção temporomandibular, e que a mesma se encontra localizada no terço inferior da face, principalmente na região da maxila, mandíbula e mento.


Introduction: the protocols of evaluation of the asymmetry facial in patients with temporomandibular disorders are, in general, realized by using cephalometric analysis, which provide the visualization, measurement and analysis of the hard tissue only. The facial analysis by computerized biophotogrammetry has been used as an auxiliary manner of diagnostic, not exposing the patient to harmful radiation, promoting the evaluation of craniofacial and muscular structures and fat layer disposition. Aim: evaluate the facial asymmetry in patients with temporomandibular disorders by computerized biophotogrammetry. Material and methods: the sample was 36 patients (31 women and 05 men) and 11 controls (06 women and 05 men) with temporomandibular disorders. For selection and classification of the sample, the Clinical Index of Fonseca (1994) was used, according to physical, dentistry and physiotherapic examination. Results: significant differences (p=0,041) were found between the mouth angle and the right and left sides in patients with temporomandibular disorders. Conclusion: alteration in facial symmetry can be observed in patients with temporomandibular disorders and it is located in lower portion of face, mainly in maxillary, mandibular and menton regions.


Subject(s)
Humans , Male , Female , Adult , Facial Asymmetry/physiopathology , Photogrammetry/methods , Temporomandibular Joint Disorders/physiopathology , Cephalometry/methods , Image Processing, Computer-Assisted
17.
Braz. dent. j ; 21(1): 55-59, Jan. 2010. tab
Article in English | LILACS | ID: lil-552355

ABSTRACT

The addition of different polymers, such as polytetrafluorethylene (PTFE), to denture base resins could be an option to modify acrylic resin mechanical properties. This study evaluated the surface hardness, impact and flexural strength, flexural modulus and peak load of 2 acrylic resins, one subjected to a long and another subjected to a short polymerization cycle, which were prepared with or without the addition of 2 percent PTFE. Four groups were formed according to the polymerization cycle and addition or not of PTFE. Forty specimens were prepared for each test (10 per group) with the following dimensions: hardness (30 mm diameter x 5 mm thick), impact strength (50 x 6 x 4 mm) and flexural strength (64 x 10 x 3.3 mm) test. The results of the flexural strength test allowed calculating flexural modulus and peak of load values. All tests were performed in accordance with the ISO 1567:1999 standard. Data were analyzed statistically by ANOVA and Tukey's test with the level of significance set at 5 percent. No statistically significant differences (p>0.05) were found for surface hardness. Flexural strength, impact strength and peak load were significantly higher (p<0.05) for resins without added PTFE. The flexural modulus of the acrylic resin with incorporated 2 percent PTFE polymerized by long cycle was significantly higher (p<0.05) than that of the other resins. Within the limits of this study, it may be concluded that the addition of PTFE did not improve the mechanical properties of the evaluated acrylic resins.


A adição de diferentes polímeros como o politetrafluoretileno (PTFE) às resinas para base de próteses removíveis pode ser uma opção para modificar as propriedades mecânicas das resinas acrílicas. Este estudo avaliou a dureza de superfície, a resistência ao impacto e à flexão, o módulo flexural e a carga de ruptura de duas resinas acrílicas, uma submetida ao ciclo longo e a outra ao ciclo curto de polimerização, as quais foram preparadas com ou sem a adição de PTFE a 2 por cento. Quatro grupos foram formados de acordo com os ciclos de polimerização e a adição ou não de PTFE. Quarenta espécimes foram preparados para cada teste (10 espécimes por grupo) com as seguintes dimensões: dureza de superfície (30 mm diametro x 5 mm espessura), resistência ao impacto (50 x 6 x 4 mm), resistência à flexão (64 x 10 x 3,3 mm). O módulo flexural e a carga de ruptura foram calculados a partir dos valores obtidos no teste de resistência à flexão. Todos os testes foram realizados em conformidade com a Norma ISO 1567:1999. Os dados foram submetidos à análise de variância e teste de Tukey com nível de significância de 5 por cento. Não foram encontradas diferenças estatisticamente significantes (p>0,05) para dureza de superfície. Os valores de resistência à flexão, resistência ao impacto e carga de ruptura foram maiores para as resinas sem a adição de PTFE (p<0,05). O valor do módulo flexural da resina acrílica com adição de PTFE a 2 por cento, polimerizada por ciclo longo, foi maior do que as outras resinas (p<0,05). Dentro das limitações deste estudo, pode-se concluir que a adição de politetrafluoretileno não melhorou as propriedades mecânicas das resinas acrílicas avaliadas.


Subject(s)
Humans , Acrylic Resins/chemistry , Dental Materials/chemistry , Polytetrafluoroethylene/chemistry , Elastic Modulus , Hardness , Hot Temperature , Materials Testing , Mechanical Phenomena , Pliability , Polymers/chemistry , Polymethyl Methacrylate/chemistry , Stress, Mechanical , Surface Properties , Time Factors
18.
Braz. dent. j ; 21(2): 130-136, 2010. tab, ilus
Article in English | LILACS | ID: lil-551933

ABSTRACT

The aim of this study was to evaluate the influence of different periodontal therapies on the integrity of indirect restorations by scanning electron microscopy (SEM). Sixty single-rooted bovine teeth were selected and randomly assigned to 12 groups. Inlay cavities were prepared in the cervical region on the center of the cementoenamel junction, and were restored with laboratory processed resin and luted with a resin cement. Twelve periodontal therapies were used (n= 5): C: control (no treatment); MS: manual scaling with Gracey curettes; US: ultrasonic scaling; PP: prophylaxis with prophylactic paste; PS: prophylaxis with pumice-stone; SBJ: sodium bicarbonate jet; MS/PP; MS/PS; MS/SBJ; US/PP; US/PS; US/SBJ. The specimens were prepared and analyzed by SEM. SEM micrographs at ×100 to ×1000 magnification were obtained from the surface of the laboratory resin and the interface of the indirect restorations. The images were evaluated by 3 skillful, calibrated, blinded observers as to the presence of grooves, microcavities and fracture of margins. The results showed that PS produced groves on restoration surface. MS and US produced groves and marginal fractures on the restorations. SBJ resulted in resin cement degradation. These results suggest that except for PS, all procedures had deleterious effects on the marginal integrity of indirect restorations.


O objetivo desse estudo foi avaliar a influência de diferentes terapias periodontais na integridade de restaurações indiretas por meio de microscopia eletrônica de varredura (MEV). Sessenta raízes bovinas foram selecionadas e aleatoriamente divididas em 12 grupos. Preparos cavitários inlay foram realizados na região cervical central da junção cemento-esmalte e restaurados com resina laboratorial cimentado com cimento resinoso. Doze terapias periodontais foram usadas (n=5): C-sem tratamento (controle); MS-raspagem manual com cureta Gracey; US-raspagem com ultra-som; PP- profilaxia com pasta profilática; PS-profilaxia com pedra pomes; SBJ-jato de bicarbonato; MS/PP; MS/PS; MS/SBJ; US/PP; US/PS; US/SBJ. As amostras foram preparados e submetidas a MEV. Imagens, de ×100 a ×1000, da superfície da resina laboratorial e da interface das restaurações indiretas foram obtidas. As imagens foram avaliadas em procedimento cego por 3 observadores habilitados previamente calibrados seguindo os seguintes critérios: ranhuras, microcavidades e fratura de margem. Os resultados mostraram que a profilaxia com pedra pomes promoveu ranhuras na superfície das restaurações. Raspagem manual e ultrasônica promoveram ranhuras e fratura de margem das restaurações. Jato de bicarbonato resultou em degradação de cimento resinoso. Os resultados sugeriram que, exceto a profilaxia com pasta profilática, todos os procedimentos resultaram em efeitos deletérios na integridade da margem das restaurações indiretas.


Subject(s)
Animals , Cattle , Dental Marginal Adaptation , Dental Scaling , Inlays , Resin Cements/chemistry , Tooth Cervix/ultrastructure , Dental Restoration Failure , Dental Restoration, Permanent/methods , Observer Variation , Random Allocation , Single-Blind Method , Stress, Mechanical , Surface Properties , Tooth Cervix/drug effects
19.
J. appl. oral sci ; 17(5): 539-543, Sept.-Oct. 2009. ilus, tab
Article in English | LILACS | ID: lil-531410

ABSTRACT

OBJECTIVES: Alterations in the temporomandibular complex can reflect in adaptations of the individual's entire muscular system, intervening with the head position and scapular waist, developing postural alterations and modifying all corporal biomechanics. The aim of this study was to evaluate the head position (HP) and head postural alterations before and after installation of occlusal splints. MATERIAL AND METHODS: Twenty patients with temporomandibular disorders (TMD) underwent clinical and postural examination, before the installation of an occlusal splint, and after 1 week and 1 month of use. RESULTS: There were statistically differences for HP, between the initial values and after 1 week of use of the occlusal device (p= 0.048) and also between 1 week and 1 month of evaluation (p= 0.001). Decrease of the painful symptomatology and maintenance of the rectification were also observed. CONCLUSIONS: The individual's postural position can suffer biomechanical alterations due to stomatognathic alterations, causing clinically visible changes in dysfunctional individuals and affecting the performance of the involved structures.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Head/anatomy & histology , Occlusal Splints , Temporomandibular Joint Disorders/therapy , Adaptation, Physiological , Centric Relation , Dental Occlusion, Centric , Follow-Up Studies , Facial Pain/therapy , Posture/physiology , Sleep Bruxism/therapy , Treatment Outcome , Young Adult
20.
Odonto (Säo Bernardo do Campo) ; 17(33): 42-47, jan.-jun. 2009. graf
Article in Portuguese | LILACS, BBO | ID: lil-542838

ABSTRACT

Introdução: alterações funcionais do complexo temporomandibular podem refletir em adaptações no sistema muscular do indivíduo, interferindo com a postura mandibular e conseqüentemente com a posição da cabeça e da cintura escapular, modificando a biomecânica corporal. Objetivo: avaliar as alterações posturais da cabeça e ombros, bem como o lado de contato prematuro e de preferência mastigatória, em pacientes com disfunção temporomandibular, antes e após o uso de placa oclusal. Materiais e Métodos: um exame clínico (intra e extra-oral) e físico foi realizado em 20 pacientes com a disfunção, antes, uma semana e um mês após o uso de um dispositivo oclusal. Resultados: os resultados demonstraram uma redução da sintomatologia dolorosa e alteração do lado de inclinação da cabeça. Conclusão: pode-se concluir que existe uma inter-relação entre a oclusão e a postura do indivíduo que pode sofrer alterações no seu funcionamento decorrente de modificações estomatognáticas.


Introduction: an altered function in temporomandibular complex can reflect in adaptations for the muscular device of the individual, intervening with the mandibular position and consequently with head and scapular waist posture, modifying the corporal biomechanics. Purpose: evaluated the postural alterations of skull and shoulders as well the contact premature side and masticatory preference side, in patients with Temporomandibular Disorder (TMD), before and after an occlusal splint insertion. Materials and Methods: Clinical (intra and extra-oral) and physical examinations were done in 20 patients with dysfunction, before, one week and one month after myorelaxant occlusal splint instalation. Results: the results showed reductions in pain symptoms and alteration of the side of head inclination. Conclusion: it can be concluded that exists an interrelation between occlusion and the postural position of the individual that can suffer alterations in its operation decurrently from stomatognathic modifications.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Mandible/physiology , Occlusal Splints , Temporomandibular Joint Dysfunction Syndrome , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL